The EtherNet/IP to PROFINET device gateway offers bi-directional data transfers between a PROFINET Controller and EtherNet/IP networks. The PLX32-EIP-PND gateway is a stand-alone DIN-rail mounted unit that provides two Ethernet ports, with each port using a different subnet.
The onboard SD Card slot (SD card optional) is used for storing configuration files that can be used for recovery, transferring the configuration to another gateway, or general configuration backup. The EtherNet/IP Driver uses Class 1 I/O connections or Class 3 Message instructions. The PROFINET driver operates as a PROFINET Class A device.
A conformal coating option is available for this product.
ProSoft Technology’s EtherNet/IP™ to Modbus® TCP/IP communication gateway allows high-speed bi-directional data transfers between Rockwell Automation® PACs and Schneider Electric® PACs. Our Modbus® TCP/IP driver features multiple client and server functionality, for faster data transmission. Two separate Ethernet ports allow each protocol to reside on separate subnets, allowing you to pass data between the two subnets without changing each device’s IP address. In addition, the gateway includes an embedded EDS Add-On Profile, allowing for simplified integration and reduced commissioning time.
A conformal coating option is available for this product.
ProSoft Technology’s EtherNet/IP™ to Siemens® Industrial Ethernet communication gateway allows high-speed bi-directional data transfers between Rockwell Automation® PACs and Siemens® S7 PACs. Two separate Ethernet ports allow each protocol to reside on separate subnets, allowing you to pass data between the two subnets without changing each device’s IP address.
In addition, the gateway includes an embedded EDS Add-On Profile, allowing for simplified integration and reduced commissioning time.
ProSoft Technology’s Modbus® TCP/IP to Siemens Industrial Ethernet gateway allows high speed bi-directional data transfers between Schneider Electric® PACs and Siemens S7 and S5 PACs.
Two ports allow each protocol to reside on separate subnets, allowing you to pass data between the two subnets without changing each device’s IP address.
ProSoft Technology’s EtherNet/IP™ to ASCII communication gateway allows high-speed bi-directional data transfers between EtherNet/IP™-enabled PACs and ASCII devices such as weigh scales and barcode readers. The EtherNet/IP™ protocol driver supports the explicit messaging implementation. The gateway is user-configurable as both a client and a server.
EtherNet/IP™ PACs include Rockwell Automation® ControlLogix® and CompactLogix™, as well as several Schneider Electric® controllers. Applications for this module are found in most industries, especially manufacturing, oil & gas, electrical power and food processing.
The gateway has several features that allow for simplified integration, reduced commissioning time and optimized performance.
ProSoft Technology’s EtherNet/IP™ to ASCII four-port communication gateway allows high-speed bi-directional data transfers between EtherNet/IP™-enabled PACs and ASCII devices such as weigh scales and barcode readers. The EtherNet/IP™ protocol driver supports the explicit messaging implementation. The gateway is userconfigurable as both a client and a server.
EtherNet/IP™ PACs include Rockwell Automation® ControlLogix® and CompactLogix™, as well as several Schneider Electric® controllers. Applications for this module are found in most industries, especially manufacturing, oil & gas, electrical power and food processing.
The gateway has several features that allow for simplified integration, reduced commissioning time and optimized performance.
The EtherNet/IP® to Modbus Serial gateway offers bi-directional data transfers between Modbus Serial and the EtherNet/IP network. Our EtherNet/IP Driver uses Class 1 I/O connections and/or Class 3 Message instructions. Protocol conversion gateways are the ideal solution for distributed networks when adding a remote rack becomes too costly.
The PLX31-EIP-MBS4 gateways are stand-alone DIN-rail mounted gateways that provide one Ethernet port for communication, allowing for remote configuration and diagnostics, and up to four (4) serial communication ports. The PLX30 gateways also come with an SD Card slot (SD card optional) for storing configuration files. In the event of a failure the SD card can be transferred to another gateway reducing downtime. These gateways also come with a wide input power range (10 Vdc – 36 Vdc), and an extended temperature range (-25°C to 70°C ). The PLX30 gateways include all the necessary cables required for communication.
A conformal coating option is available for this product.
ProSoft Technology’s EtherNet/IP™ to Modbus® TCP/IP communication gateway allows high-speed bi-directional data transfers between EtherNet/IP™ enabled controllers or devices and Modbus® TCP/IP controllers or devices.
Our Modbus® TCP/IP driver features multiple client and server functionality, for faster data transmission. In addition, the gateway includes several features, including data prioritization, that allow for simplified integration, reduced commissioning time and optimized performance.
A conformal coating option is available for this product.
ProSoft Technology’s EtherNet/IP™ to Modbus® Serial communication gateway allows high-speed bi-directional data transfers between EtherNet/IP™ PACs or devices and Modbus®-enabled PACs or devices.
EtherNet/IP™ PACs include Rockwell Automation® ControlLogix® and CompactLogix™, as well as several Schneider Electric® controllers. Modbus® Serial devices are widely used in nearly every industry and include SCADA systems and Power Monitors.
The gateway includes several features that allow for simplified integration, reduced commissioning time and optimized performance
ProSoft Technology’s EtherNet/IP™ to Siemens® Industrial Ethernet communication gateway allows high-speed bi-directional data transfers between EtherNet/IP™-enabled controllers or devices and Siemens® S7 PACs, including S7-200s, S7-300s, S7-400s, S7-1200 and S7-1500 PACs.
In addition, the gateway includes several features, including data prioritization, that allow for simplified integration, reduced commissioning time and optimized performance.
ProSoft Technology’s Modbus® TCP/IP to Modbus® Serial communication gateway allows high-speed bi-directional data transfers between Modbus® TCP/IP-enabled PACs and Modbus® Serial devices. Modbus® Serial devices are widely used in nearly every industry and include SCADA systems and Power Monitors.
In addition, the gateway has several features that allow simplified integration, reduced commissioning time and optimized performance.
A conformal coating option is available for this product.
ProSoft Technology’s Modbus® TCP/IP to Modbus® Serial four-port Serial gateway allows high-speed bi-directional data transfers between Modbus® TCP/IP-enabled PACs and Modbus® Serial devices. Modbus® Serial devices are widely used in nearly every industry and include SCADA systems and Power Monitors. Four Serial ports allow for connectivity of up to 400 Modbus® Serial devices, reducing the amount of gateways required for your application.
In addition, the gateway includes several features that allow for simplified integration, reduced commissioning time and optimized performance.
A conformal coating option is available for this product.
The EtherNet/IP™ to PROFINET® IO Device (slave) gateway offers bi-directional data transfers between EtherNet/IP™ controllers and a PROFINET® IO controller. The EtherNet/IP™ Driver supports I/O connections for guaranteed data delivery or Message instructions to send data to/from the PACs. The gateway supports 1440 bytes of input data and 1440 bytes of output data for larger applications.
In addition, the gateway’s multiple I/O connections, allow you to set different RPIs for control data and module diagnostics, enabling you to optimize your Ethernet bandwidth.
A conformal coating option is available for this product.
The PROFINET device to Modbus Serial gateway offers bi-directional data transfers between a PROFINET Controller and Modbus serial (RTU and ASCII) devices. The serial port can be configured as either a Modbus master or slave. The PROFINET interface operates as a PROFINET device (slave).
The PLX31-PND-MBS gateway is a stand-alone DIN-rail mounted unit that provides Ethernet connectivity for network communications, remote configuration, and diagnostics. The onboard SD Card slot (SD card optional) is used for storing configuration files that can be used for recovery, transferring the configuration to another gateway, or general configuration backup.
The PROFINET device to Modbus Serial gateway offers bi-directional data transfers between a PROFINET Controller and Modbus serial (RTU and ASCII) devices. Each Modbus serial port can be configured as either a Modbus master or slave. The PROFINET interface operates as a PROFINET device (slave).
The PLX31-PND-MBS4 gateway is a stand-alone DIN-rail mounted unit that provides Ethernet connectivity for network communications, remote configuration, and diagnostics. The onboard SD Card slot (SD card optional) is used for storing configuration files that can be used for recovery, transferring the configuration to another gateway, or general configuration backup.
The Modbus TCP/IP to PROFINET device gateway offers bi-directional data transfer between a PROFINET Controller and Modbus TCP/IP networks. The Modbus TCP/IP driver uses multiple clients and servers for faster data throughput. The PROFINET driver operates as a PROFINET device (slave).
The PLX32-MBTCP-PND gateways are stand-alone DIN-rail mounted units that provide two Ethernet ports for network communications, remote configuration, and diagnostics. The onboard SD Card slot (SD card optional) is used for storing configuration files that can be used for recovery, transferring the configuration to another gateway, or general configuration backup.
The Modbus TCP/IP to PROFINET device gateway offers bi-directional data transfer between a PROFINET Controller and Modbus TCP/IP networks. The Modbus TCP/IP driver uses multiple clients and servers for faster data throughput. The PROFINET driver operates as a PROFINET device (slave).
The PLX31-MBTCP-PND gateways are stand-alone DIN-rail mounted units that provide one Ethernet port for communications, remote configuration, and diagnostics. The onboard SD Card slot (SD card optional) is used for storing configuration files that can be used for recovery, transferring the configuration to another gateway, or general configuration backup.
Our gateways allow you to remotely configure and diagnose issues over an Ethernet network.
The dual-port gateways allow each protocol to reside on a separate subnet, letting you forgo having to change device IP addresses.
By using Multiple I/O communications over EtherNet/IP, you can get your data when you need it. Your control data and diagnostic data can be sent at different update rates allowing you to optimize your Ethernet bandwidth usage.
Our EtherNet/IP gateways include an embedded EDS Add-On Profile, allowing for simplified integration to your RSLogix 5000 / Studio 5000 project, reducing commissioning time.
We have training videos and a Global Tech Support team that will help you get your application up and running quickly.
In the event of a disaster, the SD card can be put in a new gateway and the configuration transferred, reducing downtime.